Skip to main content

Source Group /sourcegroup/{i}

The root OSC message for controlling a Source Group is /sourcegroup/{index}, where {index} is an integer starting from 1. To control any of the parameters listed below, you need to append the parameter name to the source group target address.

For example:

  • /sourcegroup/1/name "My Group" - Sets the name of source group 1

General Parameters

ParameterArgumentsScaleUnitCommentsSettable
/namestring------
/color[decimal, decimal, decimal, decimal]0, 1----
/lockboolean------
/muteboolean------
/azimdecimal-180, 180°--
/elevdecimal-90, 90°--
/distdecimal0, 500m--
/controlZoneIdstring------
/activeboolean------

Other Parameters

Affects

ParameterArgumentsScaleUnitCommentsSettable
/affects/selectionboolean------
/affects/positionboolean------
/affects/busRoutingboolean------
/affects/gainboolean------
/affects/muteboolean------
/affects/soloboolean------
/affects/monitoringboolean------

3D View

ParameterArgumentsScaleUnitCommentsSettable
/view3D/autoOrientationboolean------
/view3D/file3Dstring------
/view3D/scaledecimal0.01, 10----
/view3D/roll90degboolean------
/view3D/tiltdecimal-90, 90°--
/view3D/pandecimal-180, 180°--
/view3D/visibleboolean------
/view3D/labelboolean------